PK2100
Appendix E: EEPROM s E-3
Table E-1. Calibration Constants for PK2100/PK2120 EEPROM (continued)
Address Definition
0x15C
For the standard PK2100, this is current in units of 1.0 µA
corresponding to voltage output of 2.000V when set for 0-
20 mA output into nominal 392-Ω load resistor. Typically,
near 4000. For the 12-volt PK2100, the output range is 0-
15 mA.
0x15E For the standard PK2100, this is current in units of 1.0 µA
corresponding to voltage output of 10.000 V when is set
for 0-20 mA output into nominal 392-Ω load resistor. For
the 12-volt PK2100, the output range is 0-15 mA.
0x160 With shorting jumper H7 connected, these are 16-bit
numbers a
0
and a
1
high-gain plus-side inputs in the gain
formula
y = a
1
× (x
1
+ a
0
)
with the minus side grounded. If the minus side is not
grounded, the formula is
y = a
1
× ( x
1
+ a
0
) – b
1
× x
2
.
where b
1
is the minus-side gain and can be computed from
the calibration constants stored at location 0x164. The
value y is the output of the high-gain amplifier read with
universal input channel 7. The value x
1
is the plus-side
input read with universal input channel 8 and x
2
is the
minus-side input.
The coefficient a
0
is signed and is in units of 0.01 mV.
The coefficient a
1
is the unsigned dimensionless gain
expressed in units such that a gain of 10 is equal to 2000.
0x164
With shorting jumper H7 removed, these are 16-bit
numbers a
0
and a
1
high gain plus-side input in the gain
formula
y = a
1
× (x
1
+ a
0
)
with the minus side grounded. If the minus side is not
grounded, the formula becomes
y = a
1
× ( x
1
+ a
0
) – b
1
× x
2
.
where b
1
is the minus-side gain and can be computed as
a
1
– 1.
The library function up_higain() supports the default
case (H7 unjumpered).
0x168 Reserved
0x16A
Resistance of excitation resistor for high gain plus input in
units of Ω. Nominal value 10 kΩ. An unsigned integer.
continued…
Comentarios a estos manuales